[1] IEA, World energy balances: overview 2018. 2018.
[2] Miernicki E.A., Heald A.L., Huff K.D., Brooks C.S., Margenot A.J., Nuclear waste heat use in agriculture: History and opportunities in the United States. Journal of Cleaner Production, 2020, 267: 121918.
[3] Arpagaus C., Bless F., Uhlmann M., Schiffmann J., Bertsch S.S., High temperature heat pumps: Market overview, state of the art, research status, refrigerants, and application potentials. Energy, 2018, 152: 985–1010.
[4] Juhasz J.R., Novel working fluid, HFO-1336mzz(E), for use in waste heat recovery application. 12th IEA Heat Pump Conference, Rotterdam, Netherlands, 2017.
[5] Chen J., Jarall S., Havtun H., Palm B., A review on versatile ejector applications in refrigeration systems. Renewable and Sustainable Energy Reviews, 2015, 49: 67–90.
[6] Xu Y., Wang C., Jiang N., Song M., Wang Q., Chen G., A solar-heat-driven ejector-assisted combined compression cooling system for multistory building – Application potential and effects of floor numbers. Energy Conversion and Management, 2019, 195: 86–98.
[7] Xu Y., Jiang N., Han X., Han W., Mao N., Chen G., Performance evaluation and energy-saving potential comparison of a heat-powered novel compression- enhanced ejector refrigeration cycle with an economizer. Applied Thermal Engineering, 2018, 130: 1568–1579.
[8] Hao X., Wang L., Wang Z., Tan Y., Yan X., Hybrid auto-cascade refrigeration system coupled with a heat-driven ejector cooling cycle. Energy, 2018, 161: 988–998.
[9] Wang X., Yan Y., Wright E., Hao X., Gao N., Prospect evaluation of low-GWP refrigerants R1233zd(E) and R1336mzz(Z) used in solar-driven ejector-vapor compression hybrid refrigeration system. Journal of Thermal Science, 2020, 30: 1572–1580.
[10] Bai T., Lu Y., Yan G., Yu J., Performance analysis of an ejector enhanced two-stage auto-cascade refrigeration cycle for low temperature freezer. Journal of Thermal Science, 2020, 30: 2015–2026.
[11] Li Y., Yu J., Thermodynamic analysis of a modified ejector-expansion refrigeration cycle with hot vapor bypass. Journal of Thermal Science, 2019, 28: 695–704.
[12] Jeon Y., Kim D., Jung J., Jang D.S., Kim Y., Comparative performance evaluation of conventional and condenser outlet split ejector-based domestic refrigerator-freezers using R600a. Energy, 2018, 161: 1085–1095.
[13] Luo B., Zou P., Performance analysis of different single stage advanced vapor compression cycles and refrigerants for high temperature heat pumps. International Journal of Refrigeration, 2019, 104: 246–258.
[14] Guo H., Gong M., Qin X., Performance analysis of a modified subcritical zeotropic mixture recuperative high-temperature heat pump. Applied Energy, 2019, 237: 338–352.
[15] Nguyen A., Eslami-Nejad P., A transient coupled model of a variable speed transcritical CO2 direct expansion ground source heat pump for space heating and cooling. Renewable Energy, 2019, 140: 1012–1021.
[16] Hu B., Xu S., Wang R.Z., Liu H., Han L., Zhang Z., Li H., Investigation on advanced heat pump systems with improved energy efficiency. Energy Conversion and Management, 2019, 192: 161–170.
[17] Zhao Z., Tian Y., Hou F., Xing Z., Performance analysis of a refrigerant extracting twin screw compressor employed in multi-temperature heat pump systems. International Journal of Refrigeration, 2016, 67: 383–394.
[18] Wang K., Cao F., Wang S., Xing Z., Investigation of the performance of a high-temperature heat pump using parallel cycles with serial heating on the water side. International Journal of Refrigeration, 2010, 33: 1142–1151.
[19] Zhang Z., Feng X., Tian D., Yang J., Chang L., Progress in ejector-expansion vapor compression refrigeration and heat pump systems. Energy Conversion and Management, 2020, 207: 112529.
[20] Chesi A., Esposito F., Ferrara G., Ferrari L., Experimental analysis of R744 parallel compression cycle. Applied Energy, 2014, 135: 274–285.
[21] Pardiñas Á.Á., Hafner A., Banasiak K., Novel integrated CO2 vapour compression racks for supermarkets. Thermodynamic analysis of possible system configurations and influence of operational conditions. Applied Thermal Engineering, 2018, 131: 1008–1025.
[22] Schulz M., Kourkoulas D., Regulation (EU) No 517/2014 of The European Parliament and of the council of 16 April 2014 on fluorinated greenhouse gases and repealing Regulation (EC) No 842/2006. Official Journal of the European Union, 2014: L150.
[23] Flerlage H.F., Velders G.J.M., Boer J., A review of bottom-up and top-down emission estimates of hydrofluorocarbons (HFCs) in different parts of the world. Chemosphere, 2021, 283: 131208.
[24] Bai T., Yan G., Yu J., Thermodynamic assessment of a condenser outlet split ejector-based high temperature heat pump cycle using various low GWP refrigerants. Energy, 2019, 179: 850–862.
[25] Fukuda S., Kondou C., Takata N., Koyama S., Low GWP refrigerants R1234ze(E) and R1234ze(Z) for high temperature heat pumps. International Journal of Refrigeration, 2014, 40: 161–173.
[26] Malavika S., Chiranjeevi C., Raja Sekhar Y., et al., Performance optimization of a heat pump for high temperature application. MaterialstToday: Proceedings, 2021, 46: 5278–5285.
[27] Mateu-Royo C., Sawalha S., Mota-Babiloni A., Navarro-Esbrí J., High temperature heat pump integration into district heating network. Energy Conversion and Management, 2020, 210: 112719.
[28] Mota-Babiloni A., Navarro-Esbrí J., Molés F., Cervera Á.B., Peris B., Verdú G., A review of refrigerant R1234ze(E) recent investigations. Applied Thermal Engineering, 2016, 95: 211–222.
[29] Bamigbetan O., Eikevik T.M., Nekså P., Bantle M., Schlemminger C., Theoretical analysis of suitable fluids for high temperature heat pumps up to 125°C heat delivery. International Journal of Refrigeration, 2018, 92: 185–195.
[30] Bamigbetan O., Eikevik T.M., Nekså P., Bantle M., Review of vapour compression heat pumps for high temperature heating using natural working fluids. International Journal of Refrigeration, 2017, 80: 197–211.
[31] Kondou C., Koyama S., Thermodynamic assessment of high-temperature heat pumps using Low-GWP HFO refrigerants for heat recovery. International Journal of Refrigeration, 2015, 53: 126–141.
[32] Frate G.F., Ferrari L., Desideri U., Analysis of suitability ranges of high temperature heat pump working fluids. Applied Thermal Engineering, 2019, 150: 628–640.
[33] Lemmon E.W., Huber M.L., Mclinden M.O., NIST Standard ReferenceDatabase 23: Reference Fluid Thermodynamic and Transport Properties-REFPROP. 10.0, NIST NSRDS, 2018.
[34] He S., Li Y., Wang R.Z., Progress of mathematical modeling on ejectors. Renewable and Sustainable Energy Reviews, 2009, 13: 1760–1780.
[35] Liu F., Groll E.A., Study of ejector efficiencies in refrigeration cycles. Applied Thermal Engineering, 2013, 52: 360–370.
[36] Zhou M., Wang X., Yu J., Theoretical study on a novel dual-nozzle ejector enhanced refrigeration cycle for household refrigerator-freezers. Energy Conversion and Management, 2013, 73: 278–284.
[37] Sarkar J., Performance analyses of novel two-phase ejector enhanced multi-evaporator refrigeration systems. Applied Thermal Engineering, 2017, 110: 1635–1642.
[38] Helvaci H.U., Khan Z.A., Thermodynamic modelling and analysis of a solar organic Rankine cycle employing thermofluids. Energy Conversion and Management, 2017, 138: 493–510.
[39] Wu W., You T., Wang J., Wang B., Shi W., Li X., A novel internally hybrid absorption-compression heat pump for performance improvement. Energy Conversion and Management, 2018, 168: 237–251.
[40] Bai T., Yu J., Yan G., Advanced exergy analyses of an ejector expansion transcritical CO2 refrigeration system. Energy Conversion and Management, 2016, 126: 850– 861.
[41] Wang X., Yu J., An investigation on the component efficiencies of a small two-phase ejector. International Journal of Refrigeration, 2016, 71: 26–38.