Experimental Study of the Removal of Fine Particulate Matter and Moisture from Flue Gas

Expand
  • 1. CAS Key Laboratory of Advanced Energy and Power, Institute of Engineering Thermophysics, Beijing 100190, China
    2. University of Chinese Academy of Sciences, Beijing 100049, China

Online published: 2023-11-26

Supported by

This work was supported by a National Science and Technology Major Project (No. 2017-I-0009-0010).

Copyright

Science Press, Institute of Engineering Thermophysics, CAS and Springer-Verlag GmbH Germany, part of Springer Nature 2023

Abstract

Liquid desiccant systems are promising methods to recover water and waste heat simultaneously from flue gas. Prior research found that the reduction of particulate matter could occur during the absorption processes. In the present paper, experiments were carried out to explore the effect of removing fine particulate matter (PM2.5) in a liquid desiccant dehumidifier. Aqueous calcium chloride (CaCl2) was used as the desiccant in the experiments. The discrepancies in mass and energy conservation were within ±10% and ±15%, respectively, which showed the good reliability of the experimental results. Additionally, 23.5%–46.0% of the PM2.5 and 23.9%–45.1% of the moisture in the flue gas were removed. By comparing the desiccant solution and water, it was found that they could minimally remove PM2.5 through washing the flue gas. Regardless of whether the flue gas was dehumidified by water or the solution, the removal fractions of PM2.5 of these two methods could be very close if they achieve the same fraction of moisture removal. From the results of a parameter analysis, it was found that the removal fraction of PM2.5 was nearly proportional to the removal fraction of moisture within the experimental range.

Cite this article

ZHENG Xin, LU Yuan, WANG Bo, ZHAO Lifeng . Experimental Study of the Removal of Fine Particulate Matter and Moisture from Flue Gas[J]. Journal of Thermal Science, 2023 , 32(6) : 2273 -2283 . DOI: 10.1007/s11630-023-1847-2

References

[1] Liu J., Zhu F., Ma X., Industrial application of a deep purification technology for flue gas involving phase-transition agglomeration and dehumidification. Engineering, 2018, 4(3): 416–420.
[2] Zhou Q., Qin B., Ma D., et al., Novel technology for synergetic dust suppression using surfactant-magnetized water in underground coal mines. Process Safety and Environmental Protection, 2017, 109: 631–638.
[3] Black J., Cost and performance baseline for fossil energy plants Volume 1: Bituminous coal and natural gas to electricity. Final report (2nd ed), National Energy Technology Laboratory (2010 Nov), Report No: DOE20101397, 2010. 
[4] Zhang C., Yang Y., Fan L., et al., Numerical study on operating characteristics of self-driven total heat recovery system for wet-hot flue gas. Applied Thermal Engineering, 2020, 173: 115223.
[5] Elberry M.F., Elsayed A.A., Teamah M.A., et al., Performance improvement of power plants using absorption cooling system. Alexandria Engineering Journal, 2018, 57(4): 2679–2686.
[6] Fan W., Theoretical analysis of open cycle absorption heat transfer and experiment on absorber and generator. Institute of Engineering Thermophysics, Chinese Academy of Sciences, China, 2008. (in Chinese)
[7] Jessica E., Aaron V.D., Randall V.M., et al., Estimates of global mortality attributable to particulate air pollution using satellite imagery. Environmental Research, 2013, 120: 33–42.
[8] Wu H., Pan D, Hong G., et al., Removal of sulfuric acid aerosols in desulfurized flue gas by adding moist air. Journal of Chemical Technology & Biotechnology, 2017, 92(5): 1026–1034.
[9] Sui Z., Zhang Y., Norris, P., et al., Fine particulate matter emission and size distribution characteristics in an ultra-low emission power plant. Fuel, 2016, 185: 863–871.
[10] Zheng Z., Chen Z., Zhang Z., et al., Simultaneous PM2.5 and moisture removal from wet flue gas by a gas-liquid cross flow array. Process Safety and Environmental Protection, 2021, 148: 382–391. 
[11] Song C., Qiu Y., Liu Q., et al., Process intensification of cellulosic ethanol production by waste heat integration. Chemical Engineering Research and Design, 2018, 132: 115–122.
[12] Pilat M.J., Prem A., Effect of diffusiophoresis and thermophoresis on the overall particle collection efficiency of spray droplet scrubbers. Journal of the Air Pollution Control Association, 1977, 27(10): 982–988.
[13] Westerlund L., Hermansson R., Fagerström J., Flue gas purification and heat recovery: a biomass fired boiler supplied with an open absorption system. Applied Energy, 2012, 96: 444–450.
[14] Feng Z.B., Experimental study on absorber of flue gas heat recovery and soot removal. The University of Chinese Academy of Sciences, China, 2016. (in Chinese)
[15] Yin Y.G., Zheng B.J., Chen T.T., et al., Investigation on coupled heat and mass transfer coefficients between compressed air and liquid desiccant in a packed dryer. International Journal of Heat and Mass Transfer, 2016, 93: 1218–1226.