Influence of Crosswind on Evaporation Mass Transfer and Heat Exchange in High-Level Water-Collecting Natural-Draft Wet Cooling Towers

  • ZHANG Lei ,
  • ZHOU Jun ,
  • YUAN Wei ,
  • ZUO Simeng
Expand
  • 1. Department of Power Engineering, North China Electric Power University, Baoding 071003, China 
    2. Hebei Key Laboratory of Low Carbon and High Efficiency Power Generation Technology, North China Electric Power University, Baoding 071003, China

Online published: 2025-05-06

Supported by

The authors would like to acknowledge the support of the National Natural Science Foundation of China (No. 52406089, No. 52076079), Natural Science Foundation of Hebei Province, China (Grant No. E2022502052), Fundamental Research Funds for the Central Universities, China (Grant No. 2022MS081 and Grant No. 2023MS121).

Copyright

Science Press, Institute of Engineering Thermophysics, CAS and Springer-Verlag GmbH Germany, part of Springer Nature 2025

Abstract

High-level water-collecting natural-draft wet cooling towers (HNDWCTs) are commonly employed in super-large thermal and nuclear power units. However, research on the effects of crosswinds is still in the exploratory stage. This paper focuses on the fill packing zone and investigates the influence of various crosswind speeds (ranging from 1 m/s to 18 m/s) on convective and evaporation heat transfer processes in the cooling tower. The results indicate that evaporation heat transfer contributes 90% of the total, asserting a predominant role in the thermal performance of the cooling towers. Therefore, this study examines the impact of crosswinds on evaporation mass transfer in HNDWCTs. It has been observed that the “self-reflux” in high humidity region under low wind speeds is the root cause of generating low mass transfer driving force region. As wind speed exceeds 9 m/s, the “high-humidity reflux” transitions to “low-humidity reflux”, which makes the local mass transfer driving force rise back up, and helps to promote the evaporation mass transfer process. This transition mitigates the negative impact of crosswinds, resulting in the stabilization of the evaporation mass transfer and heat exchange reduction at approximately 60%.

Cite this article

ZHANG Lei , ZHOU Jun , YUAN Wei , ZUO Simeng . Influence of Crosswind on Evaporation Mass Transfer and Heat Exchange in High-Level Water-Collecting Natural-Draft Wet Cooling Towers[J]. Journal of Thermal Science, 2025 , 34(3) : 1060 -1072 . DOI: 10.1007/s11630-025-2129-y

References

[1] Zhang L., Zhou J., Zuo S.M., et al., Effect mechanism of ambient air parameters on the thermal performance for cooling towers. Journal of Thermal Science and Engineering Applications, 2024, 16(1): 011011.
[2] Claude J., Principle of a general hydraulic circuit in atmosphere cooling towers with a recovery system. In Proceedings of 3th IAHR Cooling Tower Workshop Symposium, 1982.
[3] He S.Y., Zhang G.H., Gao M., et al., Wind tunnel test on the flow resistance of U-type water collecting devices for natural draft wet cooling towers. Journal of Wind Engineering and Industrial Aerodynamics, 2019, 186: 234–240.
[4] Ma D., Research on the application of domestic high-level water collecting cooling tower technology. Henan Science and Technology, 2020, 11: 116–118. (in Chinese)
[5] Ma L.B., Ren J.X. The influence and analysis of natural crosswind on cooling characteristics of the high level water collecting natural draft wet cooling tower. IOP Conference Series: Earth and Environmental Science, 2018, 108(5): 052116.
[6] Zhu X.Y., Fu M., Comparison between high-level water collecting cooling tower and natural draft cooling tower. Energy Research and Management, 2021, 4: 106–109, 116. (in Chinese)
[7] Zhao Y.B., Sun F.Z., Long G.Q., et al., Comparative study on the cooling characteristics of high level water collecting natural draft wet cooling tower and the usual cooling tower. Energy Conversion and Management, 2016, 116: 150–164.
[8] Wang M., Wang J., Wang J.J., et al., Contrastive analysis of cooling performance between a high-level water collecting cooling tower and a typical cooling tower. Journal of Thermal Science, 2018, 27(1): 39–47.
[9] Yuan W., Sun F.Z., Zhao Y.B., Numerical study on the impact mechanism of windshield devices on frozen phenomena in a direct air-cooled system. International Journal of Heat and Mass Transfer, 2019, 142: 118206.
[10] Zhang L., Zhou J., Zuo S.M., et al., Anti-freezing mechanism of the direct air-cooled system by splitting columns operation. International Communications in Heat and Mass Transfer, 2024, 158: 107883.
[11] Yuan W., Sun F.Z., Zhao Y.B., et al., Numerical study on the influence mechanism of crosswind on frozen phenomena in a direct air-cooled system. Energies, 2020, 13(15): 3831.
[12] Chen K., Sun F.Z., Zhang L., et al., A sensitivity-coefficients method for predicting thermal performance of natural draft wet cooling towers under crosswinds. Applied Thermal Engineering, 2022, 206: 118105.
[13] Chahine A., Matharan P., Wendum D., et al., Modelling atmospheric effects on performance and plume dispersal from natural draft wet cooling towers. Journal of Wind Engineering and Industrial Aerodynamics, 2015, 136: 151–164.
[14] Lyu D.Q., Sun F.Z., Zhao Y.B., Experimental study on the air flow field in the water collecting devices. Applied Thermal Engineering, 2016, 105: 961–970.
[15] Chen G.A., Zhao Y.B., Ge W.J., et al., Critical guidelines to cope with the adverse impacts of the inner peripheral vortex in the high-level water collecting natural draft wet cooling tower. Applied Thermal Engineering, 2020, 168: 114819.
[16] Lyu D.Q., Sun F.Z., Zhao Y.B., Impact mechanism of different fill layout patterns on the cooling performance of the wet cooling tower with water collecting devices. Applied Thermal Engineering, 2017, 110: 1389–1400.
[17] Zou J., He S.Y., Long G.Q., et al., Field test on ventilation performance for high level water collecting wet cooling tower under crosswind conditions. Applied Thermal Engineering, 2018, 133: 439–445.
[18] Gao M., Zou J., He S.Y., et al., Thermal performance analysis for high level water collecting wet cooling tower under crosswind conditions. Applied Thermal Engineering, 2018, 136: 568–575.
[19] Dang Z.G., Gao M., Long G.Q., et al., Crosswind influence on cooling capacity in different zones for high level water collecting wet cooling towers based on field test. Journal of Wind Engineering and Industrial Aerodynamics, 2019, 190: 134–142.
[20] He S.Y., Zhang Z.Y., Gao M., et al., Experimental study on the air-side flow resistance of different water collecting devices for wet cooling tower applications. Journal of Wind Engineering and Industrial Aerodynamics, 2019, 190: 53–60.
[21] Zhang Z.Q., Wang M.Y., Liu Y., et al., An exploratory research on performance improvement of super-large natural draft wet cooling tower based on the reconstructed dry-wet hybrid rain zone, part 2: Crosswind effects. International Journal of Heat and Mass Transfer, 2020, 160: 120225.
[22] Zhang L., Yang Z.Y., Sun E.H., et al., Numerical simulation study on influence of equation of state on internal flow field and performance of S-CO2 compressor. Journal of Thermal Science, 2024, 33(3): 888–898.
[23] Zhang L, An G.Y., Jang. J.H, et al., Investigation of the unsteady flow mechanism in a centrifugal compressor adopted in the compressed carbon dioxide energy storage system. Journal of Energy Storage, 2024, 104: 114488.
[24] Zhang L, Yang, F, An G.Y., et al., Investigation of a rotating stall in a supercritical CO2 centrifugal compressor. Physics of Fluids, 2024, 36: 054102.
[25] Zhang L., Feng X., Yuan W., et al., Multi-objective optimization method for performance prediction loss model of centrifugal compressors. Journal of Thermal Science, 2025, 34: 590–606. 
[26] Muangnoi T., Asvapoositkul W., Wongwises S., Effects of inlet relative humidity and inlet temperature on the performance of counterflow wet cooling tower based on exergy analysis. Energy Conversion and Management, 2008, 49(10): 2795–2800.
[27] Zhao Z.G., Cooling towers and their fluid mechanics problems. Mechanics in Engineering, 1990, 2(1990): 1–5, 12. (in Chinese)
[28] Bosnjakovic F., Technische thermodinamik. Theodor Steinkopf, Dresden, 1965.
[29] Yuan W., Sun F.Z., Liu R.Q., et al., The effect of air parameters on the evaporation loss in a natural draft counter-flow wet cooling tower. Energies, 2020, 13(23): 6174.
[30] Yuan W., Zuo S.M., Zhou J., et al., Freeze protection performance of natural draft wet cooling tower with different partition water distributions. Applied Thermal Engineering, 2025, 260: 124801.

Outlines

/