Heat Transfer Model Founded and Regional Suitability Analysis of Photovoltaic Walls with Different Structures

  • ZHANG Wenjie ,
  • ZHAO Yingbo ,
  • LIU Wei ,
  • GONG Tongdan ,
  • LIU Kangyong
展开
  • 1. School of Energy and Power Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
    2. China Construction Sixth Division Construction & Development Co. Ltd., Tianjin 300451, China

网络出版日期: 2023-12-04

基金资助

This study was supported by the National Natural Science Foundation of China (Grant No. 51908287) and the Opening Funds of State Key Laboratory of Building Safety and Built Environment and National Engineering Research Center of Building Technology (Grant No. BSBE2020-7).

版权

Science Press, Institute of Engineering Thermophysics, CAS and Springer-Verlag GmbH Germany, part of Springer Nature 2022

Heat Transfer Model Founded and Regional Suitability Analysis of Photovoltaic Walls with Different Structures

  • ZHANG Wenjie ,
  • ZHAO Yingbo ,
  • LIU Wei ,
  • GONG Tongdan ,
  • LIU Kangyong
Expand
  • 1. School of Energy and Power Engineering, Nanjing University of Science and Technology, Nanjing 210094, China
    2. China Construction Sixth Division Construction & Development Co. Ltd., Tianjin 300451, China

Online published: 2023-12-04

Supported by

This study was supported by the National Natural Science Foundation of China (Grant No. 51908287) and the Opening Funds of State Key Laboratory of Building Safety and Built Environment and National Engineering Research Center of Building Technology (Grant No. BSBE2020-7).

Copyright

Science Press, Institute of Engineering Thermophysics, CAS and Springer-Verlag GmbH Germany, part of Springer Nature 2022

摘要

对不同结构的光伏墙在不同地域的传热性能和适宜性进行了研究,首先针对一维非稳态传热模型应用于多种不同结构光伏幕墙计算时存在的问题,通过对相应墙体在垂直方向上划分出多个一维非稳态传热方程的求解单元,对其中的网格节点分别求解,实现对空气层开口、空气层封闭和无空气层这三种光伏墙及普通墙体等四种结构形式中各部位温度及热流等参数的模拟计算,并结合实验数据对采用此种方法改进后的计算模型的准确性进行了验证;对比分析了不同结构形式的光伏墙体在不同气候条件的地区的适宜性条件,研究结果表明,偏重于通风散热目的的南方地区宜采用空气层开口的光伏墙,偏重于保温隔热目的的北方地区宜采用空气层封闭的光伏墙,而对于过渡地区则应根据环境条件和当地建筑情况综合考虑采取何种形式的光伏墙体。

本文引用格式

ZHANG Wenjie , ZHAO Yingbo , LIU Wei , GONG Tongdan , LIU Kangyong . Heat Transfer Model Founded and Regional Suitability Analysis of Photovoltaic Walls with Different Structures[J]. 热科学学报, 2022 , 31(6) : 1970 -1989 . DOI: 10.1007/s11630-022-1649-y

Abstract

The heat transfer performance and suitability of photovoltaic walls with different structures in different regions have been studied. First, a quasi-two-dimensional calculation model was established to realize the simulation of photovoltaic walls with three structural forms (ordinary wall with air layer opening, air layer closed and no air layer); combined with the experimental data, the accuracy of the two-dimensional calculation model was verified. Based on the simulation results, the suitability of different structural forms of photovoltaic walls in areas with different climatic conditions were compared and analyzed. The results of the study show that the southern China that emphasize the purpose of ventilation and heat dissipation should adopt photovoltaic walls with open air layers, and the northern regions that emphasize the purpose of heat preservation and heat insulation should adopt photovoltaic walls with closed air layers; for transitional areas, the type of photovoltaic wall should be considered comprehensively according to environmental conditions and local building conditions.

参考文献

[1] Li G., Zhao X., Ji J., Conceptual development of a novel photovoltaic-thermoelectric system and preliminary economic analysis. Energy Conversion and Management, 2016, 126: 935–943.
[2] Chen H.F., Ji J., Pei G., et al., Experimental and numerical comparative investigation on a concentrating photovoltaic system. Journal of Cleaner Production, 2018, 174: 1288–1298.
[3] Chen H., Li G., Y Jie., et al., Experimental and comparison study on two solar dish systems with a high concentration ratio. Journal of Thermal Science, 2019, 28: 1205–1211.
[4] Zhang C., Chao S., Shen W., et al., A review on recent development of cooling technologies for photovoltaic modules. Journal of Thermal Science, 2020, 29: 1410–1430.
[5] Liu Z.B., Li A., et al., Performance study of a quasi grid-connected photovoltaic powered DC air conditioner in a hot summer zone. Applied Thermal Engineering Design Processes Equipment Economics, 2017, 121: 1102–1110.
[6] Zhang X., Li M., Ge Y., et al., Techno-economic feasibility analysis of solar photovoltaic power generation for buildings. Applied Thermal Engineering, 2016, 108: 1362–1371.
[7] Gao F., Chen J., Lin W., Experimental study on heat dissipation performance of photovoltaic wall with ventilation channel. Building Energy Saving, 2019, 47(4): 17–20. 
[8] Luo Y.Q., Zhang L., Liu Z., et al., Performance analysis of a self-adaptive building integrated photovoltaic thermoelectric wall system in hot summer and cold winter zone of China. Energy, 2017, 140: 584–600.
[9] Omer K. Ahmed, Hamada K.I, Salih A.M., Enhancement of the performance of Photovoltaic/Trombe wall system using the porous medium: Experimental and theoretical study. Energy, 2019, 171: 14–26.
[10] Irshad K., Habib K., Thirumalaiswamy N., Implementation of photo voltaic trombe wall system for developing non-air conditioned buildings. 2013 IEEE Conference on Sustainable Utilization and Development in Engineering and Technology (CSUDET), 30-31 May 2013, Selangor, Malaysia. 
[11] Irshad K., Habib K., Thirumalaiswamy N., et al., Performance analysis of photo voltaic trombe wall for tropical climate. Applied Mechanics and Materials, 2013, 465–466: 211–215.
[12] Irshad K., Habib K., Thirumalaiswamy N., Performance evaluation of PV-trombe wall for sustainable building development. Procedia Cirp, 2015, 26: 624–629.
[13] Huang J., Xi C., Yang H., et al., Numerical investigation of a novel vacuum photovoltaic curtain wall and integrated optimization of photovoltaic envelope systems. Applied Energy, 2018, 229: 1048–1060.
[14] Luo Y., Zhang L., Liu Z., et al., Numerical evaluation on energy saving potential of a solar photovoltaic thermoelectric radiant wall system in cooling dominant climates. Energy, 2018, 142: 384–399.
[15] Yang H., Ji J., Study on the influence of BIPV on building wall heat gain. Acta Energica Sinica, 1999(3): 270–273. 
[16] Yang H., Burnett J., Jie J., Simple approach to cooling load component calculation through PV walls. Energy & Buildings, 2000, 31(3): 285–290.
[17] Jimenez M.J., Madsen H., Bloem J.J., et al., Estimation of non-linear continuous time models for the heat exchange dynamics of building integrated photovoltaic modules. Energy & Buildings, 2008, 40(2): 157–167.
[18] Friling N., Jimenez M J., Bloem H., et al., Modelling the heat dynamics of building integrated and ventilated photovoltaic modules. Energy & Buildings, 2009, 41(10): 1051–1057.
[19] Xie S., Research on thermal performance of new-type photovoltaic breathing outer wall. China University of Mining and Technology, 2017. (in Chinese)
[20] Chen X., Huang J., Zhang W., et al., Exploring the optimization potential of thermal and power performance for a low-energy high-rise building. Energy Procedia, 2019, 158: 2469–2474.
[21] Incropera F.P., DeWitt D.P., Introduction to heat transfer, thirded. John Wiley and Sons Inc., United States, 1996.
[22] Iu I.S., Experimental validation of the radiant time series method for cooling load calculations. University of Macau, China, 1999.
[23] General principles of civil building design. Ministry of Construction of the People’s Republic of China, Beijing, China, 2005.
[24] Zhang Q., Yang H., Manual of standard meteorological data for building. China Construction Industry Press, 2012. (in Chinese)